loading
CL Series Laser Chiller 1
CL Series Laser Chiller 1

CL Series Laser Chiller

According to the characteristics of laser marking equipment and the needs of different customers, this CL Series Laser Chiller is designed and manufactured with special cooling system for various lasers equipment, and it is an indispensable equipment for the laser industry.

 

Model: CL Series Laser 

MOQ: 1pcs

Price terms: FOB Guangzhou

Warranty: 1 year

After sale service: Free training service

Lead time: 

Industries:  The laser industry

    oops...!

    no product data.

    Go to homepage

    Description

    CL Series Laser Chiller 2

    Laser marking technology is the most popular industrial processing in the late 20th century. At present, the research and development, production and processing enterprises engaged in laser marking machines, laser engraving machines, laser welding machines, laser printers, laser cutting machines and other laser processing equipment are constantly emerging. The cooling system is the most critical part of the laser marking operation. 

    Product Features

    ● With microcomputer PLC control system to automatically control the whole machine operation and multi function error proof operating system.

    ● Take the original famous brand "SCHNEIDER" electrical components, ensuring the stable running and long service life.

    ● Stainless Steel water tank evaporator to avoid the solid and other metal impurities.

    ● Various models designed for different laser equipment, water temperature tolerance at ±1℃(±0.1℃) by precise digital control system. Push button operation, easy operation can hold by unprofessional personnel.

    ● Easy installation and compatible with equipment in any height. 

    ● High efficiency heat exchanger in special design, and static spraying casing with compact size.

    CA-02

    Specification

    CL Series Laser Chiller 4

    CL Series Laser chiller technical parameters
    Mode CL-0.6 CL-01 CL-1.5 CL-02 CL-03 CL-05 CL-06 CL-8(D) CL-10(D) CL-12D CL-15
    Item
    Nominal cooling capacity Kcal/h 1290 2451 2941 4446 7155 11223 13261 17630 22446 26522 35948
    50HZ/60HZ 1548 2941 3526 5332 8789 13468 15738 21156 26935 31579 43138
    KW 1.5 2.85 3.42 5.17 8.32 13.05 15.42 20.5 26.1 30.84 41.8
    50HZ/60HZ 1.8 3.42 4.1 6.2 10.22 15.66 18.3 24.6 31.3 36.72 50.16
    Total input power KW 0.795 1.22 2.02 2.18 3.37 5.03 5.81 7.85 9.89 11.8 14.7
    Power supply voltage 1PH~220V 50HZ/(60HZ) 3PH~380V 50HZ(200V/220V/415V   50HZ/60HZ)
    (110V 50HZ/60HZ)
    Refrigerant Type R22 (R134a/R407c/ R410A/R404A)
    Control mode Capillary  
    Expansion valve
    Compressor Type Hermetic rotating type Hermetic scroll type(Piston)
    Power(KW) 0.45 0.88 1.52 1.695 2.81 4.1 4.88 3.31*2 4.1*2 4.88*2 12.4
    Condenser Type High efficient finned copper tube+low noise outer rotor fan
    Cooling Air volume(m3/h) 750 1000 1500 2000 3000 5000 6000 8000 10000 12000 15000
    Evaporator Type Water tank with coil
    Chilled fluid flow (m3/h) 0.258 0.49 0.59         0.69 0.89 1.43 2.24 2.65 3.52 4.47 5.3 7.2
    0.31 0.589 1.068 1.75 2.68 3.15 4.22 5.37 6.31 8.63
    Tank volume (L) 12 15 20 20 50 55 55 110 160 160 150
    Inlet/ outlet pipe caliber 1/2" 1/2" 1/2" 1/2" 1" 1" 1" 1-1/2" 1-1/2" 2" 2"
    Drain outlet 1/2 1"
    Water pump Power(kw) 0.25 0.25 0.37 0.37 0.37 0.55 0.55 0.75 0.75 1.1 1.2
    Pump head(m) 20 20 20 20 20 20 20 20 20 20 20
    Flow switch On>3.5L/min,Off<1.4L/min On>16L/min, Off<10L/min
    Safty protection Compressor overheating , over current, high and low pressure, over temperature , flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing.
    Dimension L (mm) 530 550 600 600 930 1140 1140 1320 1530 1530 1850
    W (mm) 440 440 500 500 520 560 560 720 780 780 990
    H (mm) 780 850 950 950 1075 1140 1140 1430 1540 1540 1680
    Weight Kg 60 65 84 84 132 165 170 275 325 350 520
    Note:1.nominal cooling capacity calculated according to:Inlet/outlet chilled fluid temperature : 12℃/7℃,  Inlet/outlet cooling air temperature: 30℃/35℃;
     2. Working condition:The temperature range of chilled fluid is from 5℃ to 35℃,  Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.
     It is better to run the chiller while the ambient temperature at or below 35℃.
    We reserve the right to modify the above information without further notice.
    Get in touch with us
    If you have any enquiry about quotation or cooperation, please use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
    Related products
    no data

    HERON, make welding simple

    CONTACT US

    Contact Person: Christina Liu
    Tel: 86 20 87813325 / 86 20 87819588 / 86 20 87815075

    Fax: 86 20 87813346

    Email: info@heronwelder.com

    Address: No.63 Xin Yi Road, Taiping Town, Conghua District, Guangzhou China

    HERON, make joining simple
    Copyright © 2024 HERON Intelligent Equipment Co., Ltd. - Heron-welder.com | Sitemap
    Customer service
    detect