loading
CA Series Industrial Water Chiller 1
CA Series Industrial Water Chiller 1

CA Series Industrial Water Chiller

Air cooled water chillers provide cold water from 5℃~35℃, which is widely applied in the plastic industry, electronics, plating, chemical, ultrasonic, printing and other industrial production lines. It can precisely control the temperature, which is requested by the modernized machinery production as it can greatly improve the production efficiency and quality.

 

Model: Air cooled

MOQ: 1pcs

Price terms: FOB Guangzhou

Warranty: 1 year

After sale service: Free training service

Lead time: under 5 units one week

Industries: Plastic, electronics, plating, chemical, ultrasonic, printing and other industrial production lines.

    oops...!

    no product data.

    Go to homepage

    Description

    CA Series Industrial Water Chiller 2

    1. Air cooled water chiller is easy to install and needs to be placed in the well ventilated working condition (indoor / outdoor). This chiller unit mainly supports single, small or medium sized industrial equipment, and it is an indispensable good partner of industrial production.


    2. Air cooled water chiller is manufactured with internationally renowned accessories, and is exported to the world in batches with global warranty services. Customized design in power supply voltages and refrigerants are acceptable, which is in accordance with the working environment and the import & export standards of each country.

    原理图
    02 (2)
    1. Condenser
    02 (2)
    2. Cooling Fan
    02 (2)
    3. Angle Valve
    02 (2)
    4. Drying Filter
    02 (2)
    5. Expansion Valve
    02 (2)
    6. Automatic Water Makeup Nozzle
    02 (2)
    7. Drain Valve
    02 (2)
    8. High Pressure Switch
    02 (2)
    9. Low Pressure Switch
    02 (2)
    10. Compressor
    02 (2)
    11. Evaporator
    02 (2)
    12. Bypass Valve
    02 (2)
    13. Pump
    02 (2)
    14. Cooling Water Return
    02 (2)
    15. Cooling Water Outlet

    Specification

    CA Series Industrial Water Chiller 19

    CA Series Air cooled industrial chiller
    Mode CA-0.6 CA-01 CA-02 CA-03 CA-05 CA-06 CA-8(D) CA-10(D) CA-12(D) CA-15 CA-20(D) CA-25(D) CA-30(D) CA-40(F)  CA-50(F)  CA-60(F)
    Item
    Nominal cooling capacity Kcal/h 1290 2451 4446 7155 11223 13261 17630 22446 26522 33669 45554 52615 71896 91108 105230 136052
    50HZ/60HZ 1548 2941 5332 8789 13468 15738 21156 26918 31579 40404 55255 63743 86258 110510 127486 163262
    KW 1.5 2.85 5.17 8.32 13.05 15.42 20.5 26.1 30.84 39.15 52.97 61.18 83.6 105.94 122.36 158.2
    50HZ/60HZ 1.8 3.42 6.2 10.22 15.66 18.3 24.6 31.3 36.72 46.98 64.25 74.12 100.3 128.5 148.24 189.84
    Total input power KW 0.795 1.22 2.18 3.37 5.23 6.01 7.85 9.89 12.2 14.9 19.56 21.96 30.64 39.9 45.02 58.22
    Power supply voltage 1PH~220V 50HZ(60HZ) 3PH 380V 50HZ(200V/220V/415V   50HZ/60HZ)
    (110V 50HZ/60HZ)
    Refrigerant Type R22(R134a/R407C/R410A/R404A)
    Control mode Capillary Expansion valve
    Compressor Type Hermetic rotating  type Hermetic scroll type(Piston)
    Power(KW) 0.45 0.88 1.695 2.81 4.1 4.88 3.31*2 4.1*2 4.88*2 4.1*3 7.9*2 9.1*2 12.4*2 7.9*4 9.1*4 12.4*4
    Condenser Type High efficient finned copper tube+ low noise outer rotor fan
    Cooling Air volume(m3/h) 750 1000 2000 3000 5000 6000 8000 10000 12000 15000 20000 25000 30000 40000 50000 60000
    Evaporator Type Water tank with coil(Shell and Tube)
    Chilled fluid flow(m3/h) 0.258 0.49 0.89 1.43 2.24 2.65 3.52 4.47 5.3 7.2 9.1 10.52 14.39 18.22 21.04 27.2
    0.31 0.589 1.068 1.75 2.68 3.15 4.22 5.37 6.31 8.63 11.04 12.75 17.27 22.1 25.5 32.64
    Tank volume(L) 16 20 25 50 55 55 110 160 160 300 300 310 420 650 650 750
    Inlet/outlet pipe caliber 1/2" 1/2" 1/2" 1" 1" 1" 1-1/2" 1-1/2" 2" 2" 2" 2-1/2" 2-1/2" 3" 3" 3″
    Water pump Power(kw) 0.25 0.25 0.37 0.37 0.75 0.75 0.75 0.75 1.5 1.5 2.2 2.2 4 5.5 5.5 5.5
    Pumphead(m) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
    Safty protection Compressor overheating, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing.
    Dimension L (mm) 530 550 600 930 1140 1140 1320 1530 1530 1850 2000 2000 1850 1950 2200 2800
    W (mm) 440 440 500 520 560 560 720 780 780 990 1130 1130 1480 1800 1800 2000
    H (mm) 780 850 950 1075 1140 1140 1430 1540 1540 1680 1720 1864 1900 1870 1870 1880
    Weight Kg 58 65 84 132 161 168 272 322 350 518 598 660 930 1250 1480 1650
    Note:1. nominal cooling capacity calculated according to: Inlet/outlet chilled fluid temperature : 12℃/7℃. Inlet/outlet cooling air temperature: 30℃/35℃.2. Working condition: The temperature range of chilled fluid is from 5℃ to 35℃.  Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃. It is better to run the chiller while the ambient temperature at or below 35℃. We reserve the right to modify the above information without further notice.
    Get in touch with us
    If you have any enquiry about quotation or cooperation, please use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
    Related products
    no data

    HERON, make welding simple

    CONTACT US

    Contact Person: Christina Liu
    Tel: 86 20 87813325 / 86 20 87819588 / 86 20 87815075

    Fax: 86 20 87813346

    Email: info@heronwelder.com

    Address: No.63 Xin Yi Road, Taiping Town, Conghua District, Guangzhou China

    HERON, make joining simple
    Copyright © 2024 HERON Intelligent Equipment Co., Ltd. - Heron-welder.com | Sitemap